🏡 Breathe fresh, live fresh—your home deserves it!
The TjernlundRX2 Reversible Radon Ventilation Fan is engineered to effectively mitigate radon levels in basements and crawl spaces. Featuring two 90 CFM fans that can be individually reversed for optimal air circulation, this fan ensures a healthier living environment. Its exterior hood includes a removable screen for easy maintenance, making it a practical choice for homeowners concerned about air quality.
M**A
Great crawl space exhaust fans (I have them acting as exhaust not intake for negative air pressure)
I bought 2 of these for my duplex (purchased another 2). I sustained a lot of rain during construction and ended up with mold in my crawl space. I installed 4 of these throughout the duplex as an exhaust to create a negative air pressure in the crawl space and blow out the stale air. They are a bit on the noisy side, if you are in a noiseless, peaceful neighborhood you might not want to purchase these. The fact they are reversible is great although I do not want an intake only exhaust. They are for summer use for me. Winter time i will block them off and I am ducting a heater vent from my furnace to my crawl space (Insulated Concrete Forms) that is ultimately connected to an ERV .These fans along with a vapor barrier are a life saver. In a weeks time you will notice the stale nasty smell diminish in your crawl space. I personally dont recommend using any fan blowing outside air into the crawl space. I am more of a fan of just making negative air pressure in the crawl space but you do have the option of reversing them. They are 120v standard plug ins that need to be connected to an extension cord or you need to wire a receptacle. I wired receptacles however if you wanted to get real fancy you could wire them to a switch in your utility room. I leave them on 24x7 and will have to get down in the crawl space to plug them up for winter anyway so I didnt have a use to wire them to a switch.They are humming along spitting out the stale air as we speak.
T**T
Great for radon mitigation
My basement radon level was over 5 so I installed this through a block window vent. I set both fans to extract basement air for 12 hrs per day using a standard timer. After 3 days radon levels were below 2. I was going to have a company install the $1100 system but looks like this system will work fine. Fans are a little noisy so that is why it is off at night
G**Y
Reduced pica/l from 6.62 to 2.02.
I cut my 5"×12" hole over basement window. I then added a12"×12"×1/2" support shelf with 3 1&1/2" screws . Plug fans into surge protector. WORKS great and not to loud.
G**L
Awful Manufacturer and Amazon customer service
Awful manufacturer (Tjrenlund) and supplier (Amazon). Fan was incorrectly assembled at the factory with the rivets in backwards such that the individual fans could not be installed into the housing. I figured this out after installing two of them in my home, and it doesn't make sense to remove them after installation because the damages to the home will exceed the cost of the fans. Tom Claesgens with Tjerland promised they would address/correct the problem with some sort of field correction, then backed out and left it up to Amazon (see his email response below). Amazon initially made an unsatisfactory offer/adjustment, then their legal team retracted that.What a huge waste of time and disappointment with both Tjernland, but most especially with Amazon. What cowardice behavior!Tom ClaesgensNov 8 (6 days ago)to meWe are the manufacturer and therefore don’t do installs or service calls. HVAC companies typically are the people that do that although all sorts of electricians, plumbers, contractors or even your local handyman have and will do it.I told the gentleman I talked to that he should just remove them and send them back but he told me that they were already installed and was wondering if he could just drill out the rivets so he can get the fans in and I said that would be fine.We cannot refund your purchase because you bought them online through Amazon; you need to go through them if you want to replace them.Thanks,Tom ClaesgensTech Support/SalesTjernlund Products, Inc.1601 Ninth St.White Bear Lake, MN 55110(800) 255-4208
S**Y
A quiet option
Very quiet. Awesome
C**T
Perfect
Love it does actually what I need it to do.
R**E
Five Stars
Great product
M**N
Five Stars
Looks great . Quick shipping
K**H
Noisy
Easy to instal, everything working but two issues re: noise.- when both fans are running a droning, soft then loud, throbbing sound ( now using only one fan)- the unit is generally much louder than expected ( installed a timer switch to run unit only during the day)
Trustpilot
1 month ago
1 month ago